SIMBAD references

2009A&A...505..553Z - Astronomy and Astrophysics, volume 505553-557 (2009/10-2)

INTEGRAL and Swift/XRT observations of IGR J19405-3016.

ZHANG S., CHEN Y.P., TORRES D.F., WANG J.M., LI T.P. and GE J.Q.

Abstract (from CDS):

IGR J19405-3016 is reported in the 3rd IBIS catalog as one of its lowest significance sources (∼4.6σ under an exposure of about 371ks). This leads to a caveat in multi-wavelength studies, although the source was identified in the optical as a Seyfert 1. The currently available INTEGRAL data on the source have increased to an exposure time of ∼1376ks, which stimulates us to investigate the reality of this source again by using all the available data from INTEGRAL and Swift/XRT. We analyzed all available observations carried out by the International Gamma-Ray Astrophysics Laboratory (INTEGRAL) on IGR J19405-3016. The data were processed by using the latest version OSA 7.0. In addition, we analyzed all the available Swift/XRT data on this source. We find that IGR J19405-3016 has a detection significance of ∼9.4σ in the 20-60keV band during the observational period between March 2003 and March 2008. This confirms a real source detection reported previously. The source position and error location are therefore updated. The source is found to be constant over years at the hard X-rays. We analyzed the Swift/XRT observations on IGR J19405-3016 as well, and find that the spectrum can be fitted with a simple power law model. Over the three XRT observations, the source flux varied by up to 39% from the average, and the spectrum is generally soft. The combined XRT/ISGRI spectrum is well fitted with a simple power law model (photon index 2.11±0.03) with a column density fixed at 8.73x1020atoms/cm2. Such a photon index is consistent with the mean value 1.98 (dispersion 0.27) obtained from Swift/BAT AGN samples at 14-195keV. The spectral slope of IGR J19405-3016 is softer than the average spectral slope found elsewhere. A similar discrepancy is found with other results regarding Seyfert 1 AGNs. A possible explanation for this simple spectral description may be that the low level of the column density allows for the ``true'' spectrum to appear at soft X-rays as well.

Abstract Copyright: ∼

Journal keyword(s): X-rays: individuals: IGR J19405-3016

Simbad objects: 1

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2009A&A...505..553Z and select 'bookmark this link' or equivalent in the popup menu