SIMBAD references

2021A&A...646A.144S - Astronomy and Astrophysics, volume 646A144-144 (2021/2-1)

Fundamental physics with ESPRESSO: Towards an accurate wavelength calibration for a precision test of the fine-structure constant.

SCHMIDT T.M., MOLARO P., MURPHY M.T., LOVIS C., CUPANI G., CRISTIANI S., PEPE F.A., REBOLO R., SANTOS N.C., ABREU M., ADIBEKYAN V., ALIBERT Y., ALIVERTI M., ALLART R., ALLENDE PRIETO C., ALVES D., BALDINI V., BROEG C., CABRAL A., CALDERONE G., CIRAMI R., COELHO J., CORETTI I., D'ODORICO V., DI MARCANTONIO P., EHRENREICH D., FIGUEIRA P., GENONI M., GENOVA SANTOS R., GONZALEZ HERNANDEZ J.I., KERBER F., LANDONI M., LEITE A.C.O., LIZON J.-L., LO CURTO G., MANESCAU A., MARTINS C.J.A.P., MEGEVAND D., MEHNER A., MICELA G., MODIGLIANI A., MONTEIRO M., MONTEIRO M.J.P.F.G., MUELLER E., NUNES N.J., OGGIONI L., OLIVEIRA A., PARIANI G., PASQUINI L., REDAELLI E., RIVA M., SANTOS P., SOSNOWSKA D., SOUSA S.G., SOZZETTI A., SUAREZ MASCARENO A., UDRY S., ZAPATERO OSORIO M.-R. and ZERBI F.

Abstract (from CDS):

Observations of metal absorption systems in the spectra of distant quasars allow one to constrain a possible variation of the fine-structure constant throughout the history of the Universe. Such a test poses utmost demands on the wavelength accuracy and previous studies were limited by systematics in the spectrograph wavelength calibration. A substantial advance in the field is therefore expected from the new ultra-stable high-resolution spectrograph ESPRESSO, which was recently installed at the VLT. In preparation of the fundamental physics related part of the ESPRESSO GTO program, we present a thorough assessment of the ESPRESSO wavelength accuracy and identify possible systematics at each of the different steps involved in the wavelength calibration process. Most importantly, we compare the default wavelength solution, which is based on the combination of Thorium-Argon arc lamp spectra and a Fabry-Perot interferometer, to the fully independent calibration obtained from a laser frequency comb. We find wavelength-dependent discrepancies of up to 24m/s. This substantially exceeds the photon noise and highlights the presence of different sources of systematics, which we characterize in detail as part of this study. Nevertheless, our study demonstrates the outstanding accuracy of ESPRESSO with respect to previously used spectrographs and we show that constraints of a relative change of the fine-structure constant at the 10–6 level can be obtained with ESPRESSO without being limited by wavelength calibration systematics.

Abstract Copyright: © ESO 2021

Journal keyword(s): instrumentation: spectrographs - techniques: spectroscopic - cosmology: observations

Simbad objects: 1

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2021A&A...646A.144S and select 'bookmark this link' or equivalent in the popup menu