1995PASP..107..871H


Query : 1995PASP..107..871H

1995PASP..107..871H - Publ. Astron. Soc. Pac., 107, 871-887 (1995/September-0)

The Goddard High-Resolution Spectrograph : In-orbit performance.

HEAP S.R., BRANDT J.C., RANDALL C.E., CARPENTER K.G., LECKRONE D.S., MARAN S.P., SMITH A.M., BEAVER E.A., BOGGESS A., EBBETS D.C., GARNER H.W., HUTCHINGS J.B., JURA M., LINSKY J.L., SAVAGE B.D., CARDELLI J.A., TRAFTON L.M., WALTER F.M., WEYMANN R.J., AKE T.B., CRENSHAW D.M., MALUMUTH E.M., ROBINSON R.D., SANDOVAL J.L., SHORE S.N., WAHLGREN G.M., BRUHWEILER F., LINDLER D.J., GILLILAND R.L., HULBERT S.J. and SODERBLOM D.R.

Abstract (from CDS):

The in-orbit performance of the Goddard High Resolution Spectrograph onboard the Hubble Space Telescope (HST) is presented. This report covers the pre-COSTAR period, when instrument performance was limited by the effects of spherical aberration of the telescope's primary mirror. The digicon detectors provide a linear response to count rates spanning over six orders of magnitude, ranging from the normal background flux of 0.01 counts diode ^-1 s^-1 to values larger than 10^4 counts diode^-1 s^-1. Scattered light from the first-order gratings is small and can be removed by standard background subtraction techniques. Scattered light in the echelle mode is more complex in origin, but it also can be accurately removed.

Data have been obtained over a wavelength range from below 1100 A to 3300 A, at spectral resolutions as high as R = lambda/delta-lambda = 90,000. The wavelength scale is influenced by spectrograph temperature, outgassing of the optical bench, and interaction of the magnetic field within the detector with the earth's magnetic field. Models of these effects lead to a default wavelength scale with an accuracy better than 1 diode, corresponding to 3 km s^-1 in the echelle mode. With care, the wavelength scale can be determined to an accuracy of 0.2 diodes.

Calibration of the instrument sensitivity functions is tied into the HST flux calibration through observations of spectrophotometric standard stars. The measurements of vignetting and the echelle blaze function provide relative photometric precision to about 5% or better. The effects of fixed-pattern noise have been investigated, and techniques have been devised for recognizing and removing it from the data. The ultimate signal-to-noise ratio achievable with the spectrograph is essentially limited only by counting statistics, and values approaching 1000:1 have been obtained.


Abstract Copyright: ∼

Journal keyword(s):

Simbad objects: 4

goto Full paper

goto View the references in ADS

Number of rows : 4
N Identifier Otype ICRS (J2000)
RA
ICRS (J2000)
DEC
Mag U Mag B Mag V Mag R Mag I Sp type #ref
1850 - 2026
#notes
1 * alf CMa SB* 06 45 08.91728 -16 42 58.0171 -1.51 -1.46 -1.46 -1.46 -1.43 A0mA1Va 1610 0
2 BD+75 325 HS* 08 10 49.4903003712 +74 57 57.931973676 8.002 9.23 9.50 9.698 9.884 sdO5 267 0
3 HD 197481 BY* 20 45 09.5324974119 -31 20 27.237889841   10.05 8.627 9.078 6.593 M1VeBa1 1344 0
4 PKS J2158-3013 BLL 21 58 52.0652249880 -30 13 32.118447792   13.36 13.09 12.62   ~ 1829 1

To bookmark this query, right click on this link: simbad:objects in 1995PASP..107..871H and select 'bookmark this link' or equivalent in the popup menu