2019A&A...622A...5D


Query : 2019A&A...622A...5D

2019A&A...622A...5D - Astronomy and Astrophysics, volume 622A5-5 (2019/2-1)

Systematic effects in LOFAR data: A unified calibration strategy.

DE GASPERIN F., DIJKEMA T.J., DRABENT A., MEVIUS M., RAFFERTY D., VAN WEEREN R., BRUGGEN M., CALLINGHAM J.R., EMIG K.L., HEALD G., INTEMA H.T., MORABITO L.K., OFFRINGA A.R., OONK R., ORRU E., ROTTGERING H., SABATER J., SHIMWELL T., SHULEVSKI A. and WILLIAMS W.

Abstract (from CDS):


Context. New generation low-frequency telescopes are exploring a new parameter space in terms of depth and resolution. The data taken with these interferometers, for example with the LOw Frequency ARray (LOFAR), are often calibrated in a low signal-to-noise ratio regime and the removal of critical systematic effects is challenging. The process requires an understanding of their origin and properties.Aim. In this paper we describe the major systematic effects inherent to next generation low-frequency telescopes, such as LOFAR. With this knowledge, we introduce a data processing pipeline that is able to isolate and correct these systematic effects. The pipeline will be used to calibrate calibrator observations as the first step of a full data reduction process.
Methods. We processed two LOFAR observations of the calibrator 3C 196: the first using the Low Band Antenna (LBA) system at 42-66MHz and the second using the High Band Antenna (HBA) system at 115-189MHz.
Results. We were able to isolate and correct for the effects of clock drift, polarisation misalignment, ionospheric delay, Faraday rotation, ionospheric scintillation, beam shape, and bandpass. The designed calibration strategy produced the deepest image to date at 54MHz. The image has been used to confirm that the spectral energy distribution of the average radio source population tends to flatten at low frequencies.
Conclusions. We prove that LOFAR systematic effects can be described by a relatively small number of parameters. Furthermore, the identification of these parameters is fundamental to reducing the degrees of freedom when the calibration is carried out on fields that are not dominated by a strong calibrator.

Abstract Copyright: © ESO 2019

Journal keyword(s): surveys - catalogs - radio continuum: general - techniques: interferometric

Simbad objects: 5

goto Full paper

goto View the references in ADS

Number of rows : 5
N Identifier Otype ICRS (J2000)
RA
ICRS (J2000)
DEC
Mag U Mag B Mag V Mag R Mag I Sp type #ref
1850 - 2026
#notes
1 3C 48 QSO 01 37 41.2996631208 +33 09 35.080388820   16.62 16.20     ~ 2924 2
2 ICRF J054236.1+495107 Sy1 05 42 36.13789710 +49 51 07.2337139   18.45 17.80 17.210   ~ 1573 1
3 3C 196 Sy1 08 13 36.0561170112 +48 13 02.644966020   18.36 17.79     ~ 578 2
4 3C 295 Sy1 14 11 20.6 +52 12 09   22.34 20.80 18.54   ~ 1021 4
5 2C 1569 Bla 18 29 31.7809732968 +48 44 46.160168892   17.05 16.81 16.860   ~ 713 1

To bookmark this query, right click on this link: simbad:objects in 2019A&A...622A...5D and select 'bookmark this link' or equivalent in the popup menu