2022ApJS..259...10M


Query : 2022ApJS..259...10M

2022ApJS..259...10M - Astrophys. J., Suppl. Ser., 259, 10-10 (2022/March-1)

ALMA High-frequency Long-baseline Campaign in 2017: An Investigation of Phase-referencing Cycle Times and Effective Baseline Lengths Using Band-to-band and In-band Phase Calibration Techniques.

MAUD L.T., ASAKI Y., DENT W.R.F., HIROTA A., FOMALONT E.B., TAKAHASHI S., MATSUSHITA S., PHILLIPS N.M., SAWADA T., CORDER S. and CARPENTER J.

Abstract (from CDS):

The Atacama Large Millimeter/submillimeter Array can achieve unprecedented spatial resolutions of 15 to 5 mas with the longest baselines of 16 km and observing at the highest frequencies of 275-950 GHz (1.09-0.30 mm). Two conditions are paramount for successful observations at these frequencies: a phase calibrator in close proximity to the science target and a stable-enough atmosphere to provide a low residual phase rms post-phase-referencing. We investigate the effect of phase-referencing cycle times, for in-band and band-to-band (B2B) observing techniques, using close and distant phase calibrators, at bands 7, 8, and 9 for baselines >2000 m. We find that (1) the phase rms estimated from baselines longer than the effective baseline increases as a function of sqrt(time). (2) The expected coherence estimated using the expected phase rms corresponds well to the achieved image coherence. (3) Faster phase-referencing cycle times (<1 minute) improve phase calibration accuracy and image coherence when close phase calibrators (<2°) are used. (4) For cycle times <2 minutes the negative impact of distant phase calibrators dominates the phase error budget. We also explore whether a theoretical parameterization of the effective baseline used to estimate the phase rms and a phase stability measurement, combined with an empirical parameterization of coherence degradation as a function of calibrator separation, is suitable in estimating the expected coherence of target images. The latter proves to be more accurate. Finally, we illustrate a pragmatic approach in establishing an optimal observing strategy via dynamic cycle times and on-calibrator scan lengths.

Abstract Copyright: © 2022. The Author(s). Published by the American Astronomical Society.

Journal keyword(s): Atmospheric effects - Long baseline interferometry - Submillimeter astronomy - Phase error

Simbad objects: 8

goto Full paper

goto View the references in ADS

Number of rows : 8
N Identifier Otype ICRS (J2000)
RA
ICRS (J2000)
DEC
Mag U Mag B Mag V Mag R Mag I Sp type #ref
1850 - 2026
#notes
1 ESO 362-21 BLL 05 22 57.98464178 -36 27 30.8512953   15.26 14.62 14.48   ~ 873 2
2 3C 279 Bla 12 56 11.16657958 -05 47 21.5251510   18.01 17.75 15.87   ~ 3205 2
3 QSO B1921-293 BLL 19 24 51.05595254 -29 14 30.1210248   18.71 18.21 15.07   ~ 918 1
4 4C -02.81 BLL 21 34 10.30958988 -01 53 17.2389056   18.6 19.00 18.87   ~ 431 1
5 QSO B2134+0028 Bla 21 36 38.58632232 +00 41 54.2128562   17.30 17.08 17.02   ~ 580 2
6 [VV2006] J222852.6-075346 Bla 22 28 52.60756833 -07 53 46.6421549   19.13 18.81 18.1   ~ 68 1
7 QSO B2227-0848 Bla 22 29 40.08433313 -08 32 54.4355294   17.80 17.41 17.81   ~ 391 1
8 3C 454.3 Bla 22 53 57.7480438728 +16 08 53.561508864   16.57 16.10 15.22   ~ 3004 2

To bookmark this query, right click on this link: simbad:objects in 2022ApJS..259...10M and select 'bookmark this link' or equivalent in the popup menu