2023A&A...680A..96A


Query : 2023A&A...680A..96A

2023A&A...680A..96A - Astronomy and Astrophysics, volume 680A96 (2023/12-1)

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors I. Observations, impact on science, and modeling.

ARGYRIOU I., LAGE C., RIEKE G.H., GASMAN D., BOUWMAN J., MORRISON J., LIBRALATO M., DICKEN D., BRANDL B.R., ALVAREZ-MARQUEZ J., LABIANO A., REGAN M. and RESSLER M.E.

Abstract (from CDS):

Context. The Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data.
Aims. We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps.
Methods. We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the public Poisson_CCD code.
Results. We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10-25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Abstract Copyright: © The Authors 2023

Journal keyword(s): instrumentation: detectors - methods: data analysis - methods: numerical - infrared: general

Simbad objects: 6

goto Full paper

goto View the references in ADS

Number of rows : 6
N Identifier Otype ICRS (J2000)
RA
ICRS (J2000)
DEC
Mag U Mag B Mag V Mag R Mag I Sp type #ref
1850 - 2026
#notes
1 BD+60 1753 * 17 24 52.2753625128 +60 25 50.749843296   9.72 9.65     A1V 42 0
2 NGC 6543 PN 17 58 33.4039587288 +66 37 58.750734000   11.09 11.28     [WC] 1197 2
3 HD 189733b Pl 20 00 43.7129433648 +22 42 39.073143456           ~ 1610 1
4 * 10 Lac ** 22 39 15.6786372 +39 03 00.971152 3.650 4.670 4.880 4.98 5.19 O9V 790 0
5 * 19 PsA V* 22 42 22.0870258608 -29 21 39.773254860   7.670 6.168     M3III 34 0
6 * alf PsA PM* 22 57 39.04625 -29 37 20.0533 1.31 1.25 1.16 1.11 1.09 A4V 1303 3

To bookmark this query, right click on this link: simbad:objects in 2023A&A...680A..96A and select 'bookmark this link' or equivalent in the popup menu