2025A&A...696L...1L


Query : 2025A&A...696L...1L

2025A&A...696L...1L - Astronomy and Astrophysics, volume 696L1-6 (2025/4-1)

Making the unmodulated pyramid wavefront sensor smart II. First on-sky demonstration of extreme adaptive optics with deep learning.

LANDMAN R., HAFFERT S.Y., LONG J.D., MALES J.R., CLOSE L.M., FOSTER W.B., VAN GORKOM K., GUYON O., HEDGLEN A.D., JOHNSON P.T., KAUTZ M.Y., KUENY J.K., LI J., LIBERMAN J., LUMBRES J., McEWEN E.A., McLEOD A., SCHATZ L., TONUCCI E. and TWITCHELL K.

Abstract (from CDS):

Pyramid wavefront sensors (PWFSs) are the preferred choice for current and future extreme adaptive optics (XAO) systems. Almost all instruments use the PWFS in its modulated form to mitigate its limited linearity range. However, this modulation comes at the cost of a reduction in sensitivity, a blindness to petal-piston modes, and a limit to the sensor's ability to operate at high speeds. Therefore, there is strong interest to use the PWFS without modulation, which can be enabled with nonlinear reconstructors. Here, we present the first on-sky demonstration of XAO with an unmodulated PWFS using a nonlinear reconstructor based on convolutional neural networks. We discuss the real-time implementation on the Magellan Adaptive Optics eXtreme (MagAO-X) instrument using the optimized TensorRT framework and show that inference is fast enough to run the control loop at > 2 kHz frequencies. Our on-sky results demonstrate a successful closed-loop operation using a model calibrated with internal source data that delivers stable and robust correction under varying conditions. Performance analysis reveals that our smart PWFS achieves nearly the same Strehl ratio as the highly optimized modulated PWFS under favorable conditions on bright stars. Notably, we observe an improvement in performance on a fainter star under the influence of strong winds. These findings confirm the feasibility of using the PWFS in its unmodulated form and highlight its potential for next-generation instruments. Future efforts will focus on achieving even higher control loop frequencies (> 3 kHz), optimizing the calibration procedures, and testing its performance on fainter stars, where more gain is expected for the unmodulated PWFS compared to its modulated counterpart.

Abstract Copyright: © The Authors 2025

Journal keyword(s): instrumentation: adaptive optics - instrumentation: high angular resolution - methods: observational

Simbad objects: 3

goto Full paper

goto View the references in ADS

Number of rows : 3
N Identifier Otype ICRS (J2000)
RA
ICRS (J2000)
DEC
Mag U Mag B Mag V Mag R Mag I Sp type #ref
1850 - 2026
#notes
1 * alf Eri Be* 01 37 42.84548 -57 14 12.3101 -0.36 0.30 0.46 0.49 0.60 B6Vpe 495 1
2 V* AF Lep RS* 05 27 04.7633281608 -11 54 03.466002240   6.832 6.295     F8V(n)k: 285 0
3 * pi. Pup LP* 07 17 08.5580780520 -37 05 50.904468727 5.57 4.32 2.70 1.46 0.55 K4III 116 0

To bookmark this query, right click on this link: simbad:objects in 2025A&A...696L...1L and select 'bookmark this link' or equivalent in the popup menu